MIL-M-45424D (MU)
204.
Balls not flush . . . . . . . . . . . Visual
03007
205.
Torque to move legs (see
dwg. 8837129) . . . . . . . . . . Test
03009
206.
Torque to move brackets . . . . Test
03010
207.
Evidence of poor workmanship
(see 3.4) . . . . . . . . . . . . . Visual
03011
4.3.2.4 Ball (see dwg. 8800922 covering a detail of
dwg. 8885262).
Categorles
Defects
Code No.
Method of
Inspection
None defined
Critical:
Major:
AQL 0.40 percent
101.
Crack or split . . . . . . . . . . Visual
04001
Minor:
AQL 1.0 percent
201.
Diameter . . . . . . . . . . . . Gage
04002
202.
Evidence of poor workmanship
(see 3.4) . . . . . . . . . . . Visual
04003
4.3.2.5 Cup, well (see dwg. 8837133 covering a dstail
of dwg. 8885262).
Defects
Categories
Method of
Code No.
Inspection
None defined
Critical:
Major:
AQL 0.40 percent
101.
Flange diameter . . . . . . . . Gage
05001
AQL 0.65 percent
Minor:
201.
Evidence of poor workmanship
(see 3.4) . . . . . . . . . . . . . Visual
05002
4.3.2,6 Shipping plug (see dwg. 8857210 covering a detail
of dwg. 8885262).
Defects
Method of
Code No.
Categories
Inspection
None defined
Critical:
8