MIL-M-45424D (MU)
4.3.1.1 Process specification.-A process specification
specifiying the time, temperature and pressure ranges which
shall be maintained during production of the molded parts
shall be kept on file and available for review.
4.3.2 Examination.-The examinations listed in the
following subparagraphs shall be performed on inspection lots
(see 4.3.1) of the components or assemblies designated in the
applicable paragraph headings. Inspection for critical
defects (and major defects, when so specified) shall be 100
percent. Sampling plans for major and minor defects shall be
in accordance with MIL-STD-105 except that continuous sampling
plans in accordance with MIL-STD-1235 may be used if approved
by the Government. Instead of applying the AQL's designated
herein to the groups of major and minor defects listed, the
contractor may elect to apply AQL's to individual defects
using an AQL of 0.40 percent for each major defect and AQL of
0.65 percent for each minor defect. When this method is
elected, it shall be applied to all of the major and minor
defects listed in the applicable subparagraphs of this
section, except where 100 percent inspection is specified,
and be documented as part of the contractor's inspection
system. Equipment necessary for the performance of the
inspections listed shall be in accordance with 4.3.4.
4.3.2.1 Case (see dwg. 8800915 covering a detail of
dwg. 8885264).
Defects
Categories
Code No.
Method of
(see 6.2)
Inspection
Critical:
None defined
Major:
AQL 1.0 percent
01001
101. Case split . . . . . . . . . . .
Visual
102. Fillet to face of snap tabs
01002
improper . . . . . . . . . . . . . .
Visual
103. Start of perfect trread
incorrectly located .. . . . . . .
01003
Gage
104. Depth of thread cavity . . . .
01005
Gage
105. Depth oto botto of undercut
below threads, maximum (max.). .
01006
Gage
106. Location of well recesses . .
Gage
01007
6