MIL-C-64030(AR)
SIGNAL
FROM
TO
MCD1
J1-1
E53
MCD2
J1-14
E54
L1
E55
E25
L2
E56
E26
DET1
J1-12
E1
J1-13
DET2
E2
VHV
E7
E10
VBT
E9
J1-2
GND
E14
E20, J1-10, J1-23, J1-15
E14
GND
J1-24, J1-25, E40, E52
4.5.2.2.2 Test connections. Unless otherwise specified
herein, all test connections, adjustments and manipulations
specified for a test shall be retained throughout subsequent tests.
4.5.2.2.2.1 Loads.
Loads shall be connected as described
below.
LOAD
FROM
TO
1.5 ohm 2% 1W
DET1 (R) (J1-24)
DET1 (J1-12)
DET2 (J1-13)
1.5 ohm 2% 1W
DET2 (R) (J1-25)
See figure 6
TUBE1 (J1-16)
TUBE1 (R) (J1-3)
See figure 6
TUBE2 (R) (J1-4)
TUBE2 (J1-17)
TUBE3 (J1-18)
See figure 6
TUBE3 (R) (J1-5)
TUBE4 (J1-19)
See figure 6
TUBE4 (R) (J1-6)
See figure 6
TUBE5 (R) (J1-7)
TUBE5 (J1-20)
See figure 6
TUBE6 (J1-21)
TUBE6 (R) (J1-8)
TUBE7 (R) (J1-9)
See figure 6
TUBE7 (J1-22)
150 ohm 2% 2W
VBT (E9)
BTOK (E12)
150 ohm 2% 2W
CTOK (E16)
VBT (E9)
150 ohm 2% 2W
VBT (E9)
DALT (E15)
4400 uf 20% 30 v
CAP- (E20)
CAP+ (E7)
4.5.2.2.2.2 Power source. Set the output of a O to 15 volt
1A DC power source to 0 + 0.1 volt. Connect the negative terminal
to E14 (GND) and the positive terminal to E9 (VBT). Then set the
output voltage to 13 ± 0.5 volts.
The inputs shall
4.5.2.2.2.3 Initial input conditions.
initially be connected as described below:
INPUT TERMINAL
CONNECTED TO
SIGNAL NAME
E10
VHV
0 ± 0.2 volt
E41
DEP
0 ± 0.2 volt
E42
DA
0 ± 0.2 volt
E43
CLK
See 4.5.2.2.2.4
E44
ADATA
0 ± 0.2 volt
E45
See 4.5.2.2.2.4
DLACK
Open
All Others
89
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business