MIL-DTL-50512A
Paragraph
Title
Drawing Number
8800901
4.4.2.3
Carton, sealed
Next Higher Assembly
8800900
Category
Examination or Test
No. of
Verification Level
Requirement
Paragraph Reference /
Sample
Paragraph
Inspection Method
Units
Critical
None Defined
Major
101
Contents move when carton is shaken
III
3.3
Visual & Manual
(insufficient filler material)
102
Contents damaged so that contents are
III
3.5
Visual
exposed or liable to be exposed
Minor
201
Marking improper or unidentifiable
II
3.5
Visual
202
Evidence of poor workmanship
II
3.5
Visual
8