MIL-E-48630(AR)
4.4 Quality conformance inspection.
4.4.1 Inspection lot formation. Inspection lots shall comply
with the lot formation provision of MIL-A-48078. In addition,
inspection lots of Electronic Assemblies and Sub-assemblies shall
contain:
a. Batteries and/or power supply assemblies bearing the
same lot interfix number from one manufacturer.
b. Triple operational amplifiers bearing the same lot
interfix number from one manufacturer.
c. Integrated circuit, CMOS, target sensors bearing the
same lot interfix number from one manufacturer.
d. Integrated circuit, CMOS, timers bearing the same lot
interfix number from one manufacturer.
e. Integrated circuit, CMOS, Logic Array bearing the same
lot interfix number from one manufacturer.
Electronic assemblies of one part number only.
f.
See MIL-A-48078.
4.4.2 Examination.
a. Sampling plans. Unless otherwise specified in the
Classification of Defects and Test Tables, sampling plans and
procedures for major and minor defects shall be in accordance with
MIL-STD-105, Inspection Level II.