MIL-D-48350 (PA)
4.3.3 TESTING
4.3.3.1 Rear Panel connector ground continuity (see 3.5).-
Major Defect - Code No. 07001. This test shall be performed
100 percent in accordance with 4.4.2. Any control panel failing
to comply with all of the specified requirements shall be classed
defective and removed from the lot. (Non-destructive test)
4.3.3.2 Jettison Power (see dwg. 9287814). - Major Defect -
Code No. 07001. - This test shall be performed 100 percent in
accordance with 4.4.3. Any control panel failing to comply
with all of the specified requirements shall be classed de-
fective and removed from the lot. (Non-destructive test).
4.3.3.3 Control Panel Assembly Light Dimming. - (see dwg.
9287814) - Major defect - Code No. 07003. This test shall be
performed 100 percent in accordance with 4.4.4. Any panel fail-
ing to comply with all Of the requirements shall be classed
defective and removed from the lot. (Non-destructive test).
4.3.3.4 Press-to-test switch lighting. - (see dwg. 9287814)
Major Defect - Code No. 07004. This test shall be performed 100
percent in accordance with 4.4.5. any control panel classed
-----
defective shall be classed defective and removed from the lot.
(non-destructive test).
4.3.3.5 Firing, Mines-Pairs (see 3.6). - Major Defect -
Code No. 07005. Each control panel assembly, after having
successfully passed the test requirements of 4.4.3.1, shall
be tested in accordance with 4.4.6. Any control panel assembly
failing to comply with all of the specified requirements shall
be classed defective and removed from the lot. (Non-destructive
test).
4.3.3.6 Firing, Mines-Singles (see 3.7) - Major Defect -
Code No. 07006. Each control panel assembly, after having suc-
cessfully passed the firing, mines - pairs test requirements
of 4.3.3.6, shall be tested in accordance with 4.4.7. Any con-
trol panel assembly failing to comply with all of the specified
requirements shall be classed defective and removed from the
lot . (Non-destructive test).
4.3.3.7 Firing, Markers-pairs (see 3.8). - Major Defect -
Code No. 07007. Each control panel assembly, after having
successfully passed the mines-singles firing test requirements
11