MIL-C-48743A (PA)
4. 4.3 Testing
4. 4.3.1 Resistance (See dwg. no's, 9287553, 9287554 or
9287555 as applicable). - Major B Defect. Each charge shall
be tested for the specified requirement in accordance with
Any charge failing to meet the requirement shall
4.5.1.
(Non-destructive
be classed defective and removed from the lot.
test).
4.4.4 Inspection equipment. - The inspection equipment
required to perform the inspections and tests Prescribed in
this specification is identified in the 'Paragraph/Reference
Inspection Method' column in the tables starting with para-
graph 4.4.2.1, and the test. method paragraphs (see 4.5). The
contractor shall submit for approval, inspection equipment
designs in accordance with the terms of the contract. See
Section 6 of MIL-A-48078, and section 6.3 herein.
4.5 Test method and procedures
4.5.1 Resistance test. - The resistance between the
primer contact pin and the plug charge shall be tested using
Any sample failing to have a resistance
approved test equipment.
measurement within the required resistance range shall be
.ssed defective.
PREPARATION FOR DELIVERY
5*
Packaging. - Packaging shall be as specified on dwg.
5.1
9295002.
5.2 Packing and marking. - Packing and marking shall be
as specified on dwg. 9295002.
NOTES
6.
6.1 Intended use. - The charge covered by this specification
is intended for use In the training mine canister for purposes of
training personnel in the use of the M56 sub-system.
6.2 Ordering data. - See MIL-A-48078.
6.3 Submission of' inspection equipment designs for approval
Submit equipment designs as required to
See MIL-A-48078.
SARPA-QA-T-T, Dover,
Picatinny Arsenal; ATTN:
Commander:
New Jersey 07801.
Preparing Activity:
Custodian:
Army-PA
Army-PA
1345-A-103
Subject Number:
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business