MIL-M-63323A( AR)
3.5
Electrical
The devi ce shal l meet the
3. 5.1
Electrical performance.
electrical performance characteristics specified in TABLE I at the
temperatures specified. Method of examination and test shall be as
specified in TABLE I.
3. 5.2 Screening. All devices to be delivered in accordance
with this specification shall be subjected to the screening tests of
TABLE II in accordance with the applicable procedures for Class B
●
Interim and final electrical
devices per MIL-STD-883, Method 5004.
Lest parameters are specified in TABLE I herein.
3. 5.3 Steady state life. The devices shall be subjected to the
steady state life test of MIL-STD-883, Method 1005, Condition D and
4. 5.2 herein.
Intermediate measurements of device characteristics ,
sufficient Lo reveal both catastrophic and degradation failures,
shall be made at 360 (+120, -O) hours.
3.6 Device marking. Marking of the device shall be in
accordance with this specification and MIL-M-38510 as applicable.
The marking shall be legible and complete, and shall meet the
resistance to solvents requirements of MIL-STD-883, method 2015.
The following markings shall be placed on each device:
Index point (Pin No. 1) see DWG 9292967
a.
DWG revision letter)
b.
Part No. :
Example:
9292967X (X:
Inspection lot identification (Date Code)
c.
Manufacturer's
identification
d.
Markings a, b and c shall be placed on the top surface of the
device.
Marking d may be placed in any suitable location without
interfering with the other markings.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business