MIL-M-46984D(MU)
The filling level in the mine shall be within
3.5 Filling level
applicable limits shown in table I when examined in accordance with
4.2.4.3.
Table I.
Filling level
C a l i b r a t i o n factors
9 percent void at 40° F in a minimum mine
Expansion factor VX + 0.00046 ml/O F - ml agent
3 . 6 Workmansi
The mine shall be free from damage which could
adversely affect subsequent assembly, handling, storage, safety and
functioning.
4. QUALITY ASSURANCE PROVISIONS
4 . 1 Responsibility for inspection.
4 . 1 . 1 S u p p l i e r ' s r e s p o n s i b i l i t y . Unless otherwise specified in the
contract or purchase order, the supplier is responsible for the perfor-
mance of all inspection requirements as specified herein. Except as
otherwise specified in the contract or order, the supplier may use his
own or any other facilities suitable for the performance of the inspec-
tion requirements specified herein, unless disapproved by the Government.
The Government reserves the right to perform any of the inspections set
forth in the specification where such inspections are deemed necessary
to assure supplies and services conform to specified requirements.
4 . 1 . 2 Objective evidence. The supplier shall provide objective evi-
dence acceptable to the contracting officer that the requirements of 3.1
and 3.2 for which specific inspection has not been provided in this
s p e c i f i c a t i o n have been satisfied.