MIL-F-45060D (PA)
4.4 Quality Conformance Inspection
*4.4.1 Inspection Lot Formation. - Inspection lots shall
comply with the lot formation provisions of MIL-A-48078.
*4.4.2 Examination. - See MIL-A-48078.
a. Sampling Plans. - Unless otherwise specified in
the Classification of Defects and Test tables, sampling plans
for major and minor defects shall be in accordance with MIL-
STD-105, Inspection Level II.